product

440A 80V Hydrogen Electrolysis Rectifier

  • Input parameters: Three phase, AC380V±10% ,50HZ
  • Output parameters: DC 0~80V 0~440A
  • Cooling method: Water cooling
  • Power supply type: IGBT-based power supply
  • Application Industry: Gas Electrolysis, such as hydrogen, sulfur hexafluoride, carbon tetrafluoride, sulfur hexafluoride, ultra pure ammonia etc.

    Products Applications

    This DC power supply enables water electrolysis by converting AC grid/renewable energy into stabilized DC for hydrogen production. Over 75% of green hydrogen projects use this technology, with wind-to-hydrogen rectifiers adjusting 440A outputs within 50ms during wind fluctuations. Balancing dynamic grid stability requirements, these systems sustain the technological backbone of hydrogen economy expansion.

    440A 80V Hydrogen Electrolysis Rectifier

    SF6, offering triple air’s insulation strength, powers high-voltage applications like 345kV+ GIS switchgear (200+ kg for arc quenching) and 7nm semiconductor etching (~0.3L gas/300mm wafer). Though its GWP is 23,900× CO₂-equivalent, no alternatives match its compactness for offshore converters or precision in 3D NAND manufacturing. Industry faces a reliability-versus-sustainability dilemma.

    Application Industry

    *Photovoltaic, wind power, wave power, biomass power(green power) are connected to the power sourcerectifier and the electrolyzer to electrolyze hydrogen production

    *Electrolytic hydrogen production by power source rectifer connected to conventional power grid and integrated with electrolyzer

    *Inverter system between hydrogen energy storage and power grid

    440A 80V Hydrogen Electrolysis Rectifier

    Tetrafluoron, a compressible inert gas lacking color, odor, and flammability, enables material processing including silicon, SiO₂, Si₃N₄, PSG, and tungsten film etching. Its industrial uses span electronic component cleansing, photovoltaic cell fabrication, and precision laser applications. It also plays critical roles in gas-phase insulation, cryogenic refrigeration, space rocket attitude control, and printed circuit board detergent processes.

    In the electrolytic synthesis of sulfur hexafluoride, technicians directly add sulfur to a fluorine electrolytic cell, where it reacts to form a KHF₂-HF-S mixture. Subsequent purification steps yield high-purity SF₆. When electrolytically melting this mixture, the fluorine produced immediately reacts with the sulfur in the electrolyte and generates SF6. After adding the sulfur, the electrolytic voltage of the electrolytic cell does not increase, nor does it cause current loss.. When electrolytically melting this mixture, the fluorine produced immediately reacts with the sulfur in the electrolyte and generates SF6. After adding the sulfur, the electrolytic voltage of the electrolytic cell does not increase, nor does it cause current loss.

    Inspection Process

    Perfect inspection process and strict quality management measures to ensure excellent quality delivery

    Inspection Process

    Quality Capability

    • Quality control system ensures product quality effectively and it’s the cornerstone for us
    • *ISO 9001, ISO 14001, ISO 45001, CE, CSA certifications
    • *Rigorous quality control procedures is implemented to ensure the quality
    • *Professional quality management team to provide quality assurance for customers and partners
    Quality Capability

    Technical Parameters

    Characteristic TypesParameter ItemsTechnical Requirements

    Power Types
    Power typesHigh-frequency Power Supply
    Model and specificationsTDSB-440A80V
    Cooling modeWater-cooled
    Switch tube typeIGBT

    Input Characteristics
    Rated Input VoltageThree-phase, AC380V±10% ,50HZ
    Rated Input Power40.7KVA
    Rated Input CurrentAC 61.9A
    Input Power FactorCOSΦ≥0.95

    Output Characteristics
    Output VoltageDC  0~80V
    Output CurrentDC  0~440A
    Stabilized Current Precision≤1%(Rated Current)
    According to accuracy10A,0.01V
    Rated output efficiency≥90%

    Environmental Conditions
    Installation siteIndoor installations
    Altitude≤1500 meters
    Ambient temperature-20℃~40℃
    Relative humidity≤90%

    Control Mode
    Operating ModePLC, ADDA, Ethernet, RS485 and RS232

    Protection Characteristics
    With over voltage, over current, overload, short circuit, overheating and other abnormal self-protection function

    Optional models

    Application Model Output
    Fluoride electrolysis, SF4,SF6TBSB-9000A/12V12Vdc/9000A
    TBSB-10000A/12V12Vdc/10000A
    TBSB-6000A/15V15Vdc/6000A
    TBFBZ-13000A/9.5V9.5Vdc/13000A
    TBFBZ-13000A/10V10Vdc/13000A
    TBFBZ-15000A/10V10Vdc/15000A
    TBFBZ-18000A/11V11Vdc/18000A
    TBSB-20000A/9V9Vdc/20000A
    TBSB-10000A/15V15Vdc/10000A
    TBSB-12000A/15V15Vdc/12000A
    TBSB-24000A/15V15Vdc/24000A
    TDSB-2000A/70V70Vdc/2000A
    TDSB-2000A/90V90Vdc/2000A
    TDSB-3000A/65V65Vdc/3000A
    TDSB-1800A/80V80Vdc/1800A
    TDSB-2000A/100V100Vdc/2000A
    TDSB-6000A/50V50Vdc/6000A
    KES-7000A/150V150Vdc/7000A
    TBSB-12000A/20V20Vdc/12KA
    TBSB-13KA10V10Vdc/13KA
    TBSB-20KA10V10Vdc/20KA

    Seeking 440A 80V hydrogen electrolysis rectifier? Liyuan Haina Group, a professional manufacturer with 27+ years specializing in industrial rectifiers, supplies global clients including the US, Japan, UAE, etc. Our advanced factory delivers cost-effective Made-in-China solutions, with competitive prices and customizable options. Contact us for sales inquiries.

    Hot Tags: 440A 80V Hydrogen Electrolysis Rectifier, electrolysis rectifier efficiency, rectifier for electrolysis, electrolytic gas rectifier, Hydrogen Electrolysis Project in India, dc power supply for electrolysis, industrial rectifiers